Title
LG M50 cell aging dynamic profile testsAuthor
Publication Date
2026Version
Published versionDocument type
DatasetLanguage
EnglishRights
© Mondragon Goi Eskola PoliteknikoaAccess
Open accessPublisher’s version
https://doi.org/10.48764/k4dj-px92Publisher
Mondragon Unibertsitatea. Goi Eskola PoliteknikoaKeywords
ODS 7 Energía asequible y no contaminanteODS 9 Industria, innovación e infraestructura
ODS 13 Acción por el clima
Description
## Description of methods used for collection/generation of data:
This dataset was generated performing cyclic tests to LG M50 cells at different temperatures. This has been achieved using a Neware CT-4008-5V12A battery system, where the batteries are charged/discharged and measured. The cells tested under contrelled temperatures, 25ºC and 45ºC, in two Prebatem TFT chambers. For each temperature setting, two cells are tested for redundancy.
The tests have been programmed in the Neware system's BTS8.0 software, where a testplan with two main procedures have been implemented. These procedures are "Check-up", for State of Health monitoring and characterization, and "Cylcing", for the aging of the cells.
## Methods for processing the data:
Read each data file in tabular format, with the first row being the header. The columns are separated by "tab" in all files.
## Instrument- or software-specific information needed to interpret the data:
Any software suitable to read and process *.txt format tabular data.