Izenburua
EMI simulation of permanent magnet motor drive systemsEgilea (beste erakunde batekoa)
Beste instituzio
OronaBertsioa
Bertsio argitaratua
Eskubideak
© 2022 The AuthorsSarbidea
Sarbide irekiaArgitaratzailearen bertsioa
https://doi.org/10.1109/ACCESS.2024.3459641Non argitaratua
IEEE Access Vol. 12Lehenengo orria
133153Azken orria
133164Argitaratzailea
IEEEGako-hitzak
electric drive
electromagnetic interference (EMI)
electric machine
high frequency ... [+]
electromagnetic interference (EMI)
electric machine
high frequency ... [+]
electric drive
electromagnetic interference (EMI)
electric machine
high frequency
ODS 7 Energía asequible y no contaminante
ODS 9 Industria, innovación e infraestructura [-]
electromagnetic interference (EMI)
electric machine
high frequency
ODS 7 Energía asequible y no contaminante
ODS 9 Industria, innovación e infraestructura [-]
Gaia (UNESCO Tesauroa)
http://vocabularies.unesco.org/thesaurus/concept9505http://vocabularies.unesco.org/thesaurus/concept9508
UNESCO Sailkapena
http://skos.um.es/unesco6/2203Laburpena
With an increasing emphasis on energy efficiency and the widespread adoption of Wide-Band-Gap (WBG) devices, understanding and mitigating EMI is crucial for the reliability and performance of electric ... [+]
With an increasing emphasis on energy efficiency and the widespread adoption of Wide-Band-Gap (WBG) devices, understanding and mitigating EMI is crucial for the reliability and performance of electric drives. This research focuses on high-frequency phenomena induced in electrical machines and the integration of Finite Element Method (FEM) simulations into the drive design process. A novel approach is introduced where a full drive model is experimentally validated using motor impedance obtained from FEM simulations, which is then fitted to a lumped-parameter model with a basic genetic algorithm. The model is validated across the full Electromagnetic Compatibility (EMC) range for conducted emissions, from 10 kHz to 30 MHz. The paper emphasises the importance of an EMI-focused design approach early in the development process to minimise costs, improve reliability, and ensure compliance with EMC standards. [-]
Finantzatzailea
Gobierno VascoPrograma
Programa Predoctoral de Formación de Personal Investigador No DoctorZenbakia
PRE_2023_2_0001Laguntzaren URIa
Sin informaciónProiektua
Sin informaciónBildumak
Item honek honako baimen-fitxategi hauek dauzka asoziatuta: