<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href='static/style.xsl' type='text/xsl'?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-21T18:44:58Z</responseDate><request verb="GetRecord" identifier="oai:ebiltegia.mondragon.edu:20.500.11984/6393" metadataPrefix="mods">https://ebiltegia.mondragon.edu/oai/request</request><GetRecord><record><header><identifier>oai:ebiltegia.mondragon.edu:20.500.11984/6393</identifier><datestamp>2024-10-07T09:36:25Z</datestamp><setSpec>com_20.500.11984_1143</setSpec><setSpec>col_20.500.11984_1148</setSpec></header><metadata><mods:mods xmlns:mods="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
   <mods:name>
      <mods:namePart>Agote San Sebastian, Anartz</mods:namePart>
   </mods:name>
   <mods:name>
      <mods:namePart>Arruti Romero, Asier</mods:namePart>
   </mods:name>
   <mods:name>
      <mods:namePart>Aizpuru, Iosu</mods:namePart>
   </mods:name>
   <mods:extension>
      <mods:dateAvailable encoding="iso8601">2024-04-30T07:34:00Z</mods:dateAvailable>
   </mods:extension>
   <mods:extension>
      <mods:dateAccessioned encoding="iso8601">2024-04-30T07:34:00Z</mods:dateAccessioned>
   </mods:extension>
   <mods:originInfo>
      <mods:dateIssued encoding="iso8601">2023</mods:dateIssued>
   </mods:originInfo>
   <mods:identifier type="isbn">978-9-0758-1541-2</mods:identifier>
   <mods:identifier type="other">https://katalogoa.mondragon.edu/janium-bin/janium_login_opac.pl?find&amp;ficha_no=174088</mods:identifier>
   <mods:identifier type="uri">https://hdl.handle.net/20.500.11984/6393</mods:identifier>
   <mods:abstract>This paper presents a magnetic core test-bench that has been developed for high-frequency measurements. The bench is able to perform tests at 1 MHz, 300 V and in a range of 20 °C to 150 °C. It exhibits precise temperature control and possesses a high-power capacity, making it suitable for testing large scale magnetic cores. Comprehensive tests were conducted to validate the capabilities and performance of the test bench, and the obtained results are presented and discussed.</mods:abstract>
   <mods:language>
      <mods:languageTerm>eng</mods:languageTerm>
   </mods:language>
   <mods:accessCondition type="useAndReproduction">© 2023 IEEE and EPE Association</mods:accessCondition>
   <mods:subject>
      <mods:topic>Core loss</mods:topic>
   </mods:subject>
   <mods:subject>
      <mods:topic>Experimental testing</mods:topic>
   </mods:subject>
   <mods:subject>
      <mods:topic>Test bench</mods:topic>
   </mods:subject>
   <mods:titleInfo>
      <mods:title>A High Frequency Magnetic Test Bench with Fast Isothermal Measurements for Large Cores</mods:title>
   </mods:titleInfo>
   <mods:genre>http://purl.org/coar/resource_type/c_c94f</mods:genre>
</mods:mods></metadata></record></GetRecord></OAI-PMH>