<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href='static/style.xsl' type='text/xsl'?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-11T21:43:25Z</responseDate><request verb="GetRecord" identifier="oai:ebiltegia.mondragon.edu:20.500.11984/5754" metadataPrefix="mods">https://ebiltegia.mondragon.edu/oai/request</request><GetRecord><record><header><identifier>oai:ebiltegia.mondragon.edu:20.500.11984/5754</identifier><datestamp>2024-03-05T11:30:36Z</datestamp><setSpec>com_20.500.11984_473</setSpec><setSpec>col_20.500.11984_478</setSpec></header><metadata><mods:mods xmlns:mods="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
   <mods:name>
      <mods:namePart>Milikua, Aritz</mods:namePart>
   </mods:name>
   <mods:extension>
      <mods:dateAvailable encoding="iso8601">2022-10-18T16:38:18Z</mods:dateAvailable>
   </mods:extension>
   <mods:extension>
      <mods:dateAccessioned encoding="iso8601">2022-10-18T16:38:18Z</mods:dateAccessioned>
   </mods:extension>
   <mods:originInfo>
      <mods:dateIssued encoding="iso8601">2011</mods:dateIssued>
   </mods:originInfo>
   <mods:identifier type="issn">0033-2097</mods:identifier>
   <mods:identifier type="other">https://katalogoa.mondragon.edu/janium-bin/janium_login_opac.pl?find&amp;ficha_no=119955</mods:identifier>
   <mods:identifier type="uri">https://hdl.handle.net/20.500.11984/5754</mods:identifier>
   <mods:abstract>The paper presents overview of high-order harmonics compensation methods applied for control of grid-connected converter. Two harmonic compensation methods are presented. One based on band-pass filers cooperating with Direct Power Control with Space Vector Modulation (DPC-SVM) is dedicated for renewable energy interface. Second method based on resonant controllers applied in Voltage Oriented Control (VOC) adds an active filtering function to PWM rectifier. Simulation and preliminary experimental results for these two methods are presented.</mods:abstract>
   <mods:language>
      <mods:languageTerm>eng</mods:languageTerm>
   </mods:language>
   <mods:accessCondition type="useAndReproduction">Attribution-NonCommercial-NoDerivatives 4.0 International</mods:accessCondition>
   <mods:accessCondition type="useAndReproduction">http://creativecommons.org/licenses/by-nc-nd/4.0/</mods:accessCondition>
   <mods:accessCondition type="useAndReproduction">© 2011 Przegląd Elektrotechniczny</mods:accessCondition>
   <mods:subject>
      <mods:topic>grid-connected converter</mods:topic>
   </mods:subject>
   <mods:subject>
      <mods:topic>harmonic distortion</mods:topic>
   </mods:subject>
   <mods:subject>
      <mods:topic>harmonic compensation</mods:topic>
   </mods:subject>
   <mods:subject>
      <mods:topic>power quality</mods:topic>
   </mods:subject>
   <mods:subject>
      <mods:topic>active filters</mods:topic>
   </mods:subject>
   <mods:titleInfo>
      <mods:title>Higher harmonics compensation in grid-connected PWM converters for renewable energy interface and active filtering</mods:title>
   </mods:titleInfo>
   <mods:genre>http://purl.org/coar/resource_type/c_6501</mods:genre>
</mods:mods></metadata></record></GetRecord></OAI-PMH>