<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href='static/style.xsl' type='text/xsl'?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-10T11:06:39Z</responseDate><request verb="GetRecord" identifier="oai:ebiltegia.mondragon.edu:20.500.11984/5598" metadataPrefix="rdf">https://ebiltegia.mondragon.edu/oai/request</request><GetRecord><record><header><identifier>oai:ebiltegia.mondragon.edu:20.500.11984/5598</identifier><datestamp>2024-03-04T17:16:28Z</datestamp><setSpec>com_20.500.11984_1143</setSpec><setSpec>col_20.500.11984_1148</setSpec></header><metadata><rdf:RDF xmlns:rdf="http://www.openarchives.org/OAI/2.0/rdf/" xmlns:ow="http://www.ontoweb.org/ontology/1#" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:ds="http://dspace.org/ds/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/rdf/ http://www.openarchives.org/OAI/2.0/rdf.xsd">
   <ow:Publication rdf:about="oai:ebiltegia.mondragon.edu:20.500.11984/5598">
      <dc:title>Reactive Power Limits of Single-Phase and Three-Phase DC-Link VSC STATCOMs under Negative-Sequence Voltage and Current</dc:title>
      <dc:creator>Marzo Elguero, Iosu</dc:creator>
      <dc:creator>Barrena, Jon Andoni</dc:creator>
      <dc:creator>Abad, Gonzalo</dc:creator>
      <dc:contributor>Sánchez Ruiz, Alain</dc:contributor>
      <dc:contributor>Muguruza Fernández de Valderrama, Ignacio</dc:contributor>
      <dc:subject>Industrial electronics</dc:subject>
      <dc:subject>Reactive power</dc:subject>
      <dc:subject>Multilevel converters</dc:subject>
      <dc:subject>Power distribution</dc:subject>
      <dc:subject>Voltage</dc:subject>
      <dc:subject>Power system harmonics</dc:subject>
      <dc:subject>Automatic voltage control</dc:subject>
      <dc:description>This paper analyzes and compares the reactive power limits of single- and three-phase configured dc-link Voltage Source Converter (VSC) structures for Static Synchronous Compensator (STATCOM) to operate with negative-sequence voltage and current. The three-level Neutral Point Clamped (3L NPC) is used as an example of a three-phase dc-link topology. Likewise, the Cascaded H-Bridge (CHB) is used as a single-phase dc-link case, in both star and delta configurations. Modular Multilevel Converter is also considered as a combination of both dc-link configurations. The conclusions drawn are generic whichever the Power Electronics Building Block (PEBB) used in each VSC structure.</dc:description>
      <dc:date>2022-06-08T16:31:07Z</dc:date>
      <dc:date>2022-06-08T16:31:07Z</dc:date>
      <dc:date>2021</dc:date>
      <dc:type>http://purl.org/coar/resource_type/c_c94f</dc:type>
      <dc:identifier>978-166543554-3</dc:identifier>
      <dc:identifier>2577-1647</dc:identifier>
      <dc:identifier>https://katalogoa.mondragon.edu/janium-bin/janium_login_opac.pl?find&amp;ficha_no=166809</dc:identifier>
      <dc:identifier>https://hdl.handle.net/20.500.11984/5598</dc:identifier>
      <dc:language>eng</dc:language>
      <dc:rights>© 2021 IEEE</dc:rights>
      <dc:publisher>IEEE</dc:publisher>
   </ow:Publication>
</rdf:RDF></metadata></record></GetRecord></OAI-PMH>