Simple record

dc.contributor.authorElorza Azpiazu, Leire
dc.contributor.authorMoreno, Yerai
dc.contributor.authorEgea, Aritz
dc.contributor.authorAlmandoz, Gaizka
dc.contributor.authorAngulo, Ainara
dc.date.accessioned2024-11-21T16:37:12Z
dc.date.available2024-11-21T16:37:12Z
dc.date.issued2024
dc.identifier.isbn979-8-3503-7060-7en
dc.identifier.issn2473-2087en
dc.identifier.otherhttps://katalogoa.mondragon.edu/janium-bin/janium_login_opac.pl?find&ficha_no=178521en
dc.identifier.urihttps://hdl.handle.net/20.500.11984/6814
dc.description.abstractThe ageing of insulation systems in electric machines can compromise partial discharge-free designs. Regularly monitoring insulation health is crucial to prevent unexpected failures. Several authors have proposed health markers from impedance spectroscopy and partial discharge analysis. Nevertheless, no comparative study has evaluated their sensitivity as health monitoring techniques for complete windings tested until failure. This paper compares both techniques for a thermally aged electric machine winding until failure, with impedance spectrum and partial discharge measurements taken every 24 hours. Markers from impedance spectroscopy (resonance frequency, impedance above/below resonance frequency, and capacitance) and partial discharge measurements (partial discharge inception voltage and charge) were compared considering: (1) deteriorated insulation identification, (2) sensitivity to changes in the insulation, and (3) near breakdown indication ability. While impedance spectroscopy markers varied with ageing, partial discharge analysis proved more meaningful. Regular monitoring of partial discharge inception voltage and charge can identify deteriorated insulation and prompt necessary maintenance.en
dc.language.isoengen
dc.publisherIEEEen
dc.rights© 2024 IEEEen
dc.subjectElectric machinesen
dc.subjectFault Diagnosisen
dc.subjectImpedanceen
dc.subjectPartial Discharge (PD)en
dc.subjectThermal stressesen
dc.subjectODS 7 Energía asequible y no contaminantees
dc.subjectODS 9 Industria, innovación e infraestructuraes
dc.subjectODS 11 Ciudades y comunidades sostenibleses
dc.subjectODS 12 Producción y consumo responsableses
dc.subjectODS 13 Acción por el climaes
dc.titleComparison of impedance spectroscopy and partial discharge analysis as insulation health diagnosis techniquesen
dcterms.accessRightshttp://purl.org/coar/access_right/c_f1cfen
dcterms.sourceInternational Conference on Electrical Machines (ICEM)en
local.contributor.groupAccionamientos aplicados a la tracción y a la generación de energía eléctricaes
local.description.peerreviewedtrueen
local.identifier.doihttps://doi.org/10.1109/ICEM60801.2024.10700230en
oaire.format.mimetypeapplication/pdfen
oaire.file$DSPACE\assetstoreen
oaire.resourceTypehttp://purl.org/coar/resource_type/c_c94fen
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85en
dc.unesco.tesaurohttp://vocabularies.unesco.org/thesaurus/concept621en
oaire.funderNameGobierno Vascoen
oaire.funderIdentifierhttps://ror.org/00pz2fp31 / http://data.crossref.org/fundingdata/funder/10.13039/501100003086en
oaire.fundingStreamElkartek 2023en
oaire.awardNumberKK-2023-00091en
oaire.awardTitleEquipos de Potencia en Gallium Nitride (EPOGAN)en
oaire.awardURISin informaciónen
dc.unesco.clasificacionhttp://skos.um.es/unesco6/3306en