Share
Title
Influence of the test-chamber shape on the performance of conductometric gas sensorsPublished Date
2022Publisher
ElsevierKeywords
Computational fluid dynamics (CFD)Conductometric gas sensor
Gas flow
Chamber-position influence
Abstract
In this article, CFD simulations results are presented as a key tool to the comprehension of the target gas concentration evolution in a test chamber, at different working conditions. The simulation r ... [+]
In this article, CFD simulations results are presented as a key tool to the comprehension of the target gas concentration evolution in a test chamber, at different working conditions. The simulation results are compared with the experimental data, which shows a qualitative good correlation with the evolution of the concentration gradient detected. The experiments were carried out using an aluminum gas test chamber, where a WO3 based conductometric sensor is introduced. The results demonstrate how the response time is dependent on the sensor working conditions. Analyzing the CFD and experimental results, some assumptions for this behavior are proposed.
The WO3 sensor needs a Pt heating element, which is heated up to 300 °C. As the response is highly temperature-dependent, the temperature distribution on the sensor surface was measured by an IR thermographic camera. The simulation results show that the temperature distribution matches with those obtained experimentally. To validate the model, a mesh and time step convergence study was also implemented. [-]
Publisher’s version
https://doi.org/10.1016/j.snb.2022.131694ISSN
0925-4005Published at
Sensors and Actuators B: Chemical Vol. 361. N. artículo 131694. June, 2022Document type
Article