Izenburua
Current References Limitation Method Considering Voltage and Current Maximums for STATCOMs Providing Simultaneously Reactive Power and Current HarmonicsEgilea (beste erakunde batekoa)
Argitalpen data
2022Beste erakundeak
Ingeteam (Spain)Bertsioa
PostprintaDokumentu-mota
ArtikuluaArtikuluaHizkuntza
IngelesaEskubideak
© 2022, IEEESarbidea
Sarbide irekiaArgitaratzailearen bertsioa
https://doi.org/10.1109/JESTPE.2022.3146203Non argitaratua
IEEE Journal of Emerging and Selected Topics in Power Electronics Vol. 10. N. 2. Pp. 2559-2575, 2022Argitaratzailea
IEEEGako-hitzak
Automatic voltage control
Harmonic analysis
Reactive power
Power harmonic filters ... [+]
Harmonic analysis
Reactive power
Power harmonic filters ... [+]
Automatic voltage control
Harmonic analysis
Reactive power
Power harmonic filters
Power electronics
Active filters
Limiting
Current harmonic control
Current loops
Static synchronous compensator (STATCOM)
Voltage and current maximums [-]
Harmonic analysis
Reactive power
Power harmonic filters
Power electronics
Active filters
Limiting
Current harmonic control
Current loops
Static synchronous compensator (STATCOM)
Voltage and current maximums [-]
Laburpena
This article focuses the analysis on a static synchronous compensator (STATCOM) that operates simultaneously providing reactive power and several current harmonics of different frequencies (active pow ... [+]
This article focuses the analysis on a static synchronous compensator (STATCOM) that operates simultaneously providing reactive power and several current harmonics of different frequencies (active power filter or active impedance functionalities). Being more specific, this article proposes a general limitation method that reduces the current references of the STATCOM whenever the current or voltage limit of the converter is exceeded. In a realistic operation scenario, the STATCOM’s operator may ask for certain reactive power and harmonic current reference signals, and depending on the actual grid voltage conditions (unbalances and harmonics), the required converter voltage and current may exceed their limit. Consequently, the proposed limitation method protects the STATCOM system from malfunctioning when the voltage limit is exceeded and from damages when the current limit is exceeded. Hence, this article first proposes a limitation method oriented to a STATCOM that operates solely exchanging reactive power. Second, the limitation method is generalized for a STATCOM that controls reactive power as well as several current harmonics. Then, simulation and experimental results are provided to validate the proposed limitation method, under a rich variety of working conditions. Finally, a conceptual analysis of the method is carried out confronting it against several possible limitation alternatives. [-]
Sponsorship
Gobierno de EspañaProjectu ID
info:eu-repo/grantAgreement/GE/Convocatoria MISIONES CDTI/MIG-20201002/ES/Nuevo Sistema energético 100% flexible y robusto para la integración de nuevas tecnologías en generación, redes y demanda/FLEXENERBildumak
Related items
Showing items related by title, author, creator and subject.
-
Vibration attenuation of conductive beams by inducing eddy currents
Irazu, Leire; Elejabarrieta, Maria Jesus (IOP, 2016)The increasing requirements for structural vibration control in many industries, require innovative attenuation techniques. In this work, the phenomenon of eddy currents is proposed to reduce the ... -
Analysis and Design Guidelines for Current Control Loops of Grid-Connected Converters Based on Mathematical Models
Abad, Gonzalo; Milikua, Aritz (MDPI AG, 2020)Having a method for analyzing and designing regulators of controls that contain many current loops such as active filters is not a trivial task. There can be many parameters of regulators and filters that must be carefully ... -
Static Current Unbalance of Paralleled SiC MOSFET Modules in the Final Layout
Garrido, David; Baraia-Etxaburu, Igor (IEEE, 2020)Silicon Carbide (SiC) MOSFETs enable enhanced performance of power converters in several applications. Parallel connection of SiC MOSFETs become mandatory for medium power applications due to the current rate of existing ...