New Calibration method to measure Rake Face Temperature of the tool during Dry Orthogonal Cutting using Thermography
(Elsevier Ltd., 2018)
A new method for measuring temperature in the rake face of a tool during dry orthogonal cutting using ther-
mography is presented. In addition, a new technique is also used to calibrate the infrared camera. Using ...
Uncertainty of Temperature Measurements in Dry Orthogonal Cutting of Titanium Alloys
(Elsevier, 2015)
Infrared radiation thermometer is used to measure the temperature of tool during dry orthogonal cutting of titanium alloys. The accuracy of measured temperature depends on several parameters such as the experimental set-up, ...